Stage

  • Proscenium Opening: 35' 
  • Stage Right Wing Space: 17'
  • Stage Left Wing Space: 14' 
  • Curtain Line to Upstage Wall: 34'
  • Curtain Line to Downstage Edge: 11' 
  • Orchestra Pit Cover Depth: 6'
  • Curtain Line to Cyc: 26' 
  • Crossover Space/Cyc to upstage wal: 8’

Sound
The Tonne Playhouse has a professional full range stereo sound system consisting of two line array speaker clusters flown on the left and right side of the stage. Sub bass cabinets are located at floor level.  Audio system components:

MAIN PA:  
db technologies T12 powered line array 4
db technologies T8 powered line array 8
line array frame kit 2
30’ manual chain hoist 2
db technologies 218 powered sub 2
   
MAIN PA DRIVE:  
DBX Drive rack 1
DBX 231 EQ 1
DBX 160 2
Behringer Ultra Curve 2
1x American Audio dual cd w controller 1
1x Behringer NOX1010 sub mixer 1
2x Sony CDR 2
   
EQ/ XO/ Play back/ comp:  
Ashly 4001 XO 1
Ashly 2001 XO 2
Rane XO 3 way 2
Rane 231 EQ 3
Denon DN300-2 2
DBX 166 1
DBX 166XL 1
   
AUDIO MIXERS:  
Yamaha M7CL-48 V3 1
Midas M32 console w case 1
Midas 32 input digital stage box 1
A&H zed 14 mixer 1
Mackie 1204 VLZ mixer 1
Mackie 402 VLZ mixer 1
   
MICROPHONES:  
SM58 3
SM57 8
SM81 3
Beta 58 7
Beta 52 1
Beta 91 1
Sennheiser MD421U 1
Sennheiser EVO 3 drum mic 3
Sennheiser E945 1
AKG D112 1
AKG C-214 2
AT Condenser 3
mm psm ear worn hs mic 18
crown pcc 160 2
LXI studio combo 2
   
DI:  
Hot Box 2
ultra DI 1
DB1 2
Ramtech DI 4
   
ASSISTIVE LISTENING:  
Williams T45 assistive listening base 1
Williams T45 assistive listening belt pack 4
Williams T45 assistive listening neck loop 2
   
WIRELESS:  
Shure UR4 receivers 3
Shure J4 receiver 4
Shure ULXD4 receiver 4
SM58 Wireless TX (UR/UHF) 4
B58 wireless TX (J4/ UHF) 2
B58 wireless TX ULD 6
UR TX beltpack 6
ULD TX beltpack 16
Shure Antenna Splitter w/ Paddle 1
Shure SM58 Wireless capsule 2
Shure B87 wireless capsule 1
   
CLEAR COM:  
Clear Com Base station 1
Clear com Speaker/Mic Panel 2
Clear com Belt pack w/ headset 10
PI Belt pack w/ headset 2
   
MIC STANDS:  
tall roundbase short teleboom 10
Tall tripod non tele boom 10
Straight stand 6
Short tripod short teleboom 5
Short round base short teleboom 3
   
SPEAKERS:  
EV ZLXP spaeker w/ stand 4
EV SX300 speaker w/ stand & 2x foot 4
EAW JF 115 6
McCaully 212 wedge 4
Renkus Heinz 7YE speakers 6
Renkus Heinz 6” FR 3
Renkus 215 sub 2
Rammsdell 118 speakers 2
Community 112 wedge 4
JBL 112 MR speakers 2
JBL 115 TR speaker 2
Peavey 115 speaker 2
Peavey 112 speaker 2
Samson Powered sub 1
   
AMPLIFIERS:  
Crest CA 9000 5
Renkus Heinz 3500 4
behringer NUKE! 1
QSC mx blue face 2
Crown Macro Tech 24x6 8

Road Power

  • (1) 400 amp per leg 3-phase service located off stage right in Scene Shop

Lighting 

CONTROL:  
Hog 3 widget 4 univ w/ ps & usb 1
Hog 3 Play back wing w/ ps & usb 3
Hog 3 Programmer w/ ps & usb 1
Elo 17” touch screen 2
Full Boar 4 console w/ case 1
Hog 4 master wing 1
   
FIXTURES:  
S4 ers 36
S4 par ea 30
S4 Parnel 2
Chauvet slim par 22
Chauvet rogue R2 led wash 14
Vari Lite VLZ 18
Robert Juliat Alice 600W LED FS w/ stand 2
   
SPLITTERS:  
Data Stream 4way DMX Splitter 2
Fleenor Design 5 way DMXSplitter 1
   
MBALL:  
20” mirror ball w/ motor 1
   
ATMOSPHERE:  
Chauvet Hurricane 1800 Flex Fogger 1
Look Solutions Viper Hazer 1
   
DISTRO:  
Applied 8 way Socopex w/ 3x20A Access 1
   
DIMMER RACK:  
Strand CD80 96 ch 1
Strand CEM for CD80 2


Rigging

  • Locking Rail: Stage left
  • Loading Bridge: Grid height
  • Counterweight Lines: (21) single purchase line sets holding 1500 each
  • Batten Length: 40'
  • 3 line sets dedicated to Electrics
  • 1 line set dedicated to 18' x 24' front projection screen

Draperies

  • Legs : (4) Sets black, (1) Set red
  • Borders: (4) Black, (1) Red
  • Travelers: (1) upstage, (1) midstage
  • Scrim: (1)
  • Cyc: (1) Seamless sky blue

Intercom
The Central Park Performing Arts Center has a two-channel Clear-Com system with (9) 501 belt packs with headset and (1) RM220 base stations. The outlets are located as follows:

  • Dressing room
  • Orchestra pit
  • Stage left, back and front
  • Stage right, back and front
  • Scene shop
  • Dimmer room
  • Ticket office
  • Spot bays, left and right
  • Vestibule, left and right
  • Control room

Projection

Kramer 8x4 HD matrix
Kramer VP 728 Switcher
Kramer Video splitter 1x4
Kramer Video splitter 1x2
NEC NP4100 Video Projector
9x12 rear screen w frame
20x30’ DA-Lite Roll Up Front Screen
9X16 DA-LITE HD REAR SCREEN
PANASONIC PROJECTOR 13K LUMEN
PANASONIC PROJECTOR 10K LUMEN
PANASONIC SHORT THROW LENS
PANASONIC LONG THROW LENS
PANASONIC MED THROW LENS

 

Loading
The loading dock leads into a 23' x 39' scene shop which leads to upstage right. The loading dock is elevated 3' from ground level and has a 10' wide x 12' high door.

Dressing Rooms
There are two dressing rooms:

  • Women's: 13' x 17'
  • Men's: 13' x 14' 

Each dressing room has a toilet, shower, (4) sinks and a clothing rack. The Green Room is 33' x 8'. It is equipped with mirrors, furniture and a telephone.

Other Amenities Available

  • Baldwin 6' Baby Grand Piano (on Stage)
  • Stage Risers: (4) 8' x 6' x 24" with skirting, (2) stair units
  • Lectern
  • Step Ladders
  • Genie Lift
  • Ramp

Backstage Regulations
The CPPAC's Technical Supervisor or House Technician will assist with all technical needs and requirements. The authority of the Technical Supervisor with regards to safety issues and CPPAC's equipment will be absolute. The Lessee and/or Performers shall provide the Technical Supervisor with a full and detailed outline of show requirements, not less than 15 days prior to the first occupancy of the premises, including all stage, lighting, sound and hall requirements (schematics) and such other information as may be appropriate to the event to be presented. The Lessee and/or Performer shall provide, not less than 7 days prior to the first occupancy of the premises, with a written production schedule, outlining all details for your event.

Example:
8 am - 9 am Load in
9 am - 10 am Sound set up
10 am - 11 am Sound check
11 am - 12 pm Doors
12 pm - 2 pm Show
2 pm - 3 pm Load out

SAFETY PROVISIONS: The Lessee and/or Performer agrees that all drapes, hangings, curtains, drops, and other decorative materials used in the premises shall be flame-proof and that all matters involving safety be resolved by the decision of the Lessor.

CARE AND USE OF THE THEATER: The Lessee and/or Performer shall not use any type of tape, adhesives or drive any nails, screws, tacks, pins, and/or any other objects into the floors, walls, partitions, doors, seats, or woodwork of the premises without the authority of the Technical Supervisor. 

THE USE OF CONFETTI, GLITTER OR OBJECTS THAT MEASURE LESS THAN 1/4" IN SIZE/DIAMETER IS STRICTLY PROHIBITED.